Specifications

From the manufacturer's product information.

Capacity

Ajax devices
up to 250
Users
up to 200
Automation scenarios
up to 64
Security groups
up to 25
Rooms
up to 50
Event log
up to 1,000 events

Wired communication

Line connection
4–core cable
Input
8 Fibra lines
Fibra line length
up to 6,550 ft
Power supply of devices
up to 14.4 W
Output voltage range
23–25.1 V⎓
Maximum rated output
0.53 A
Maximum output peak-to-peak ripple voltage
220 mV⎓
Topologies
Beam (Radial wiring); Ring; Tree
Polling interval
from 12 s to 300 s

Wireless communication

Frequency bands
865.0–868.0 MHz; 868.0–868.6 MHz; 868.7–869.2 MHz; 869.4–869.65 MHz
Maximum effective radiated power (ERP)
up to 25 mW
Radio signal modulation
GFSK
Radio communication range
up to 11,450 ft; up to 9,800 ft
Polling interval
from 12 s to 300 s

Photo verification

Photo verification types
Photo by alarm; Photo by scenario; Photo on demand; Photo by schedule; Photo by arming/disarming; Photo by anti-masking; Photo by tamper alarm; Photo by magnetometer
Photo delivery time
up to 9 s
Photo resolution
up to 960 × 720 pixels
Number of photos in a series
from 1 to 5

Monitoring

Supported protocols
SIA DC-09 (SIA-DCS); SurGard (Contact ID); ​​ADEMCO 685; Other proprietary protocols
Event types
System alarms and events; Panic button coordinates; Photo verification

Sabotage protection

Protection against spoofing
device authentication

Power supply

Device operating AC voltage range
100–240 V, 50/60 Hz
Device operating DC voltage range
10.5–15 V⎓
Autonomous operation
up to 60 hours; Battery power saver mode allows extending the backup battery life.
Low battery voltage
11.7 V⎓
Low battery recovery voltage
12.9 V⎓
End-of-life battery voltage
11 V⎓
Minimum backup battery energy level in the charged state
100%

Current consumption

Maximum at nominal voltage
240 mA
Quiescent at nominal voltage
up to 102 mA; up to 61 mA