Awernica
Superior Hub Hybrid (4G) (without casing)
Lifecycle status unknown
Ajax Systems

Ajax Systems Superior Hub Hybrid (4G) (without casing)

Category
Intrusion Panel
First seen by Awernica
Nov 2026

Keep every device you have installed in one list – firmware, lifecycle and replacements. No card.

Latest Firmware

Not specified

No verified firmware data

Lifecycle Status

Not published

Ajax Systems does not publish lifecycle or end-of-life data

Replacement

Not specified

No verified replacement

On your sites?

Add to a site

Track firmware, EOL and replacements for every device you have installed – in one list.

Specifications

From the manufacturer's product information.

Capacity

Ajax devices
up to 100
Users
up to 50
Automation scenarios
up to 32
Security groups
up to 9
Rooms
up to 50
Event log
up to 1,000 events

Wired communication

Line connection
4-core cable
Input
8 Fibra lines
Fibra line length
up to 6,550 ft
Power supply of devices
up to 14.4 W
Output voltage range
23–25.1 V⎓
Maximum rated output
0.53 A
Topologies
Beam (Radial wiring); Ring; Tree
Devices polling interval
from 12 to 300 s

Wireless communication

Frequency bands
866.0–866.5 MHz; 868.0–868.6 MHz; 868.7–869.2 MHz; 905.0–926.5 MHz; 915.85–926.5 MHz; 921.0–922.0 MHz; 866.0 – 866.5 MHz; 868.0 – 868.6 MHz; 868.7 – 869.2 MHz; 905.0 – 926.5 MHz; 915.85 – 926.5 MHz; 921.0 – 922.0 MHz
Maximum effective radiated power (ERP)
up to 25 mW
Radio signal modulation
GFSK
Radio communication range
up to 6,550 ft; up to 5,600 ft
Polling interval
from 12 s to 300 s

Photo verification

Photo verification types
Photo by alarm; Photo by scenario; Photo on demand; Photo by schedule
Photo delivery time
up to 9 s
Photo resolution
up to 640 × 480 pixels
Number of photos in a series
from 1 to 5 pictures

Monitoring

Supported protocols
SIA DC-09 (SIA-DCS); SurGard (Contact ID); ​​ADEMCO 685; Other proprietary protocols
Event types
System alarms and events; Panic button coordinates; Photo verification

Sabotage protection

Protection against spoofing
device authentication

Power supply

Device operating AC voltage range
100–240 V, 50/60 Hz
Device operating DC voltage range
10.5–15 V⎓
Autonomous operation
up to 60 hours
Low battery voltage
11.7 V⎓
Low battery recovery voltage
12.9 V⎓
End-of-life battery voltage
11 V⎓
Maximum output peak-to-peak ripple voltage
220 mV⎓
Minimum backup battery energy level in the charged state
100%

Current consumption

Maximum at nominal voltage
240 mA
Quiescent at nominal voltage
up to 102 mA; up to 61 mA

New here?

Awernica keeps your installed devices and systems up to date.

  • Firmware & end-of-life tracking
  • Cross-manufacturer spec search
  • Site lists and equipment plans
  • Earn Credits – unlock Pro tools without paying

No card · 7-day Pro trial included

See a real site first