
Lifecycle status unknown
Ajax Systems Superior MegaHub
Category
Intrusion Panel
First seen by Awernica
Nov 2026
Keep every device you have installed in one list – firmware, lifecycle and replacements. No card.
Latest Firmware
Not specified
No verified firmware data
Lifecycle Status
Not published
Ajax Systems does not publish lifecycle or end-of-life data
Replacement
Not specified
No verified replacement
On your sites?
Add to a site
Track firmware, EOL and replacements for every device you have installed – in one list.
Specifications
From the manufacturer's product information.
Capacity
- Ajax devices
- up to 9991
- Users
- up to 1,000
- Access codes
- up to 1,000
- Access control devices
- up to 1,000 Tag key fobs and Pass cards
- Automation scenarios
- up to 100
- Security groups
- up to 100
- Rooms
- up to 500
- Event log
- up to 1,000 events
Wired communication
- Line connection
- 4-core cable
- Input
- 8 Fibra lines
- Fibra line length
- up to 6,500 ft
- Power supply of devices
- up to 1.2 A per one Fibra line; up to 1.6 A in total for all Fibra lines
- Output voltage range
- 22–25 V⎓
- Topologies
- Beam (Radial wiring); Ring; Tree
- Device polling interval
- 12 to 300 s
Wireless communication
- Frequency bands
- 865.0–868.0 MHz; 868.0–868.6 MHz; 868.7–869.2 MHz; 869.4–869.65 MHz
- Maximum effective radiated power (ERP)
- up to 25 mW
- Radio signal modulation
- GFSK
- Radio communication range
- up to 8,200 ft
- Device polling interval
- 12 s to 300 s
Photo verification
- Photo verification types
- By alarm; By scenario; On demand; By schedule; By arming/disarming; By masking attempt; By tamper alarm; By magnetometer alarm
- Photo delivery time
- up to 9 s
- Photo resolution
- up to 960 × 720 pixels
- Number of photos in a series
- 1 to 5
Monitoring
- Supported protocols
- SIA DC-09 (SIA-DCS); SurGard (Contact ID); ADEMCO 685; Other proprietary protocols
- Event types
- System alarms and events; Panic button coordinates; Photo verification
Sabotage protection
- Protection against spoofing
- device authentication
Power supply
- Main power supply type
- type A
- Device operating AC voltage range
- 100–240 V, 50/60 Hz
- Device operating DC voltage range
- 10.5–15 V⎓
- Autonomous operation
- up to 60 hours
- Low battery voltage
- 11.7 V⎓
- Low battery recovery voltage
- 12.7 V⎓
- End-of-life battery voltage
- 10.5 V⎓
- Maximum output peak-to-peak ripple voltage
- 1.2 V⎓
- Minimum backup battery energy level in the charged state
- 100%
Current consumption
- Maximum at nominal voltage
- 220 mA
- Quiescent at nominal voltage2
- up to 178 mA; up to 170 mA
New here?
Awernica keeps your installed devices and systems up to date.
- Firmware & end-of-life tracking
- Cross-manufacturer spec search
- Site lists and equipment plans
- Earn Credits – unlock Pro tools without paying
No card · 7-day Pro trial included
See a real site first