Supported
Acre SPCP355.300
Category
Expander
First seen by Awernica
Nov 2026
Keep every device you have installed in one list – firmware, lifecycle and replacements. No card.
Latest Firmware
Not specified
No verified firmware data
Lifecycle Status
Active
Current product
Replacement
Not specified
No verified replacement
On your sites?
Add to a site
Track firmware, EOL and replacements for every device you have installed – in one list.
Specifications
From the manufacturer's product information.
- Number of on-board zones
- 8
- EOL resistor
- Dual 4K7 (default), other resistor combinations selectable
- Relay outputs
- 3 (single-pole changeover, 30 V DC / max. 1 A resistive switching current)
- Interfaces
- X-BUS (in, out, branch)
- Tamper contact
- Front / back tamper
- Mains voltage
- 230 VAC, + 10%/ -15%, 50 Hz
- Operating current
- Max. 245 mA at 12 VDC (all relays activated)
- Quiescent current
- Max. 195mA at 12 VDC
- Output voltage
- 13-14 VDC in normal conditions (mains powered and fully charged battery)
- Operating temperature
- 0 ~ +40 °C
- Colour
- RAL 9003 (signal white)
- Weight
- 18.400 kg (housing incl. cover), 11.300 kg (housing without cover)
- Dimensions (W x H x D)
- 498 x 664 x 157 (mm)
- Housing
- Metal housing (1.5 mm mild steel)
- Approval
- DE: VdS G112125, Klasse C AT: W 1300923/11 E, Klasse WS
- Electronic outputs
- 3 supervised (each max. 400 mA resistive switching current)
- Auxiliary power (nominal)
- Max. 2360 mA at 12 V DC (8 separately fused outputs, max. 300mA per output)
- Battery type
- YUASA NP24-12 (12 V 24 Ah), Alarmcom AB1227-0 (12 V 27 Ah), (batteries not supplied with product)